Plate structure
·Thickness 50-100mm, front 1.5mm
·Made of stainless steel with basalt wool sandwiched in the middle
·Heat resistance temperature > 1000°C
·Possesses soundproofing, fireproofing, moisture-proofing, and thermal insulation properties
·Comply with the safety requirements for food contact materials
Multiple Doors and Observation Window Configuration
·Multiple interconnected doors can be configured, with at least one door equipped with a high-temperature tempered glass observation window for real-time monitoring of the disinfection status
Sealing design
·Enterprise style double-sided double-layer interlocking structure, with high-temperature resistant sealing rings at the junction of the door panel and the box body, providing excellent sealing performance
Heating system
·380V electric finned heating tube, customized specification 4KW/piece
·The heat dissipation area of tubular electric heating tubes is increased by 2.5-4 times compared to ordinary light tubes, and the surface load is increased by 2-3 times
·The heating tube is set on the side walls near the ground around the box, with the lower end 20-30cm above the ground, which improves the efficiency of hot air circulation.
Hot air circulation system
·Configure a high-temperature resistant fan to form a closed-loop loop through "fan → supply air duct → heating tube cavity → disinfection box → air outlet" to ensure temperature uniformity inside the cabin
Bottom plate design
·On the basis of this, a 3mm thick anti slip aluminum plate is added, with a smooth and anti slip surface, and a height 1-2cm higher than the outdoor ground to prevent water from flowing back. Compliant with GB 31654-2021 hygiene standards
Real time temperature display and remote monitoring
·Real time display of temperature and equipment operation status at each monitoring point on the control panel
Timeout protection and security mechanism
·Set a timeout control device to force a power outage if the disinfection time exceeds 2 hours
·When the temperature inside the disinfection room is above 60 ℃, the door body should be protected from touch warning. Only when the temperature is below 50 ℃ can the door be opened to ensure safe operation
One click start and automatic timing
·The integrated control panel supports one click start of heating pipes, fans, and monitoring devices, and automatically shuts down with a delay after reaching the set temperature,
Intelligence and voice control
·Support networked data transmission, enabling remote monitoring and control management through mobile apps
·Support voice control, can realize voice start stop, voice set disinfection time temperature and other functions
High temperature sterilization and hot air drying
·Maintaining a high temperature of 90-100 ℃ for ≥ 10 minutes, combined with hot air circulation, achieves a sterilization rate of 99.9%,
Total power/voltage
·36KW / 380V
Product dimensions
·7.28㎡x2550H